Selecting the correct blind flange requires more than matching the nominal pipe size. Its outside diameter, thickness, bolt circle diameter, bolt-hole arrangement, pressure class, material, and facing must all match the piping system’s requirements.
This Blind Flange Size Chart explains common nominal pipe sizes, DN equivalents, pressure classes, flange dimensions, and measurement methods. It also covers different blind flange types, materials, applications, and selection considerations.
Whether you are replacing an existing flange, closing a pipeline, installing industrial equipment, or checking a piping specification, understanding these measurements helps prevent connection problems. This guide focuses on commonly used ASME flange sizing conventions while explaining where other standards may differ.
What Is a Blind Flange?
A blind flange is a solid, circular flange without a central opening. It is designed to close the end of a pipe, valve, pressure vessel nozzle, or other flanged connection.
Unlike a standard pipe flange, which allows fluid to pass through its bore, a blind flange blocks the opening completely. It is generally installed with a compatible gasket, bolts, and nuts to create a sealed connection.
Blind flanges are commonly used in industrial piping systems where a pipeline needs to be isolated, closed, inspected, or prepared for future expansion.
Main Features of a Blind Flange
Important features include:
- Solid construction: There is no central pipe opening.
- Bolt holes: Used to connect the blind flange to a mating flange.
- Sealing face: Provides the contact surface for the gasket.
- Outside diameter: Determines the overall flange size.
- Flange thickness: Provides the required structural dimensions.
- Pressure class: Identifies the applicable pressure-temperature rating category.
- Material specification: Determines the material properties and suitability for the service.
The exact design depends on the manufacturing standard, nominal size, pressure class, material, and facing type.
Blind Flange Size Chart: NPS and DN
Blind flanges are commonly identified by Nominal Pipe Size (NPS) in North American piping systems. International and metric specifications often use Nominal Diameter (DN).
NPS and DN are nominal designations rather than exact measurements of the flange’s outside diameter. For example, a 4-inch NPS blind flange is not 4 inches across its outer edge.
The following chart provides common NPS and corresponding DN designations.
Common Blind Flange Nominal Sizes
| Nominal Pipe Size (NPS) | DN Designation | Nominal Size (inches) |
|---|---|---|
| 1/2″ | DN 15 | 0.5 |
| 3/4″ | DN 20 | 0.75 |
| 1″ | DN 25 | 1 |
| 1 1/4″ | DN 32 | 1.25 |
| 1 1/2″ | DN 40 | 1.5 |
| 2″ | DN 50 | 2 |
| 2 1/2″ | DN 65 | 2.5 |
| 3″ | DN 80 | 3 |
| 3 1/2″ | DN 90 | 3.5 |
| 4″ | DN 100 | 4 |
| 5″ | DN 125 | 5 |
| 6″ | DN 150 | 6 |
| 8″ | DN 200 | 8 |
| 10″ | DN 250 | 10 |
| 12″ | DN 300 | 12 |
| 14″ | DN 350 | 14 |
| 16″ | DN 400 | 16 |
| 18″ | DN 450 | 18 |
| 20″ | DN 500 | 20 |
| 24″ | DN 600 | 24 |
These are common nominal size equivalents. The actual dimensions of a blind flange depend on its applicable dimensional standard and pressure class.
Understanding NPS and DN Designations
NPS is widely used in American piping specifications, while DN is commonly used in metric-based systems.
For example:
- NPS 2 is commonly associated with DN 50.
- NPS 4 is commonly associated with DN 100.
- NPS 6 is commonly associated with DN 150.
- NPS 8 is commonly associated with DN 200.
- NPS 12 is commonly associated with DN 300.
These designations help identify the nominal connection size, but they do not establish that two flanges from different standards are interchangeable.
Standard Blind Flange Dimensions
A blind flange has several important dimensions that determine whether it can fit and connect correctly to a mating flange.
Important Blind Flange Measurements
| Dimension | Description | Abbreviation |
|---|---|---|
| Outside diameter | Total diameter across the flange | OD |
| Thickness | Thickness of the main flange body | T |
| Bolt circle diameter | Diameter through bolt-hole centers | BCD |
| Bolt-hole diameter | Diameter of each bolt opening | — |
| Number of bolt holes | Total number of fastening holes | — |
| Raised face diameter | Diameter of the raised sealing surface | RF |
| Raised face height | Height of the raised sealing surface | — |
| Ring groove dimensions | Dimensions of an RTJ sealing groove | — |
These measurements should be checked together rather than using only the outside diameter to identify a flange.
Outside Diameter of a Blind Flange
The outside diameter is the measurement across the widest part of the flange. It is one of the easiest dimensions to measure and is useful for identifying the general flange size.
However, different pressure classes can have different outside diameters for the same nominal pipe size.
Blind Flange Thickness
Thickness refers to the main solid body of the flange. Blind flanges are generally designed with thickness requirements that account for the pressure-containing function of the component.
Thickness can vary considerably according to nominal size, pressure class, material, and design standard.
Do not assume that a blind flange and a corresponding weld neck flange have the same thickness.
Bolt Circle Diameter
The bolt circle diameter is the diameter of an imaginary circle passing through the centers of the bolt holes.
It is also known as the pitch circle diameter (PCD) in metric specifications.
The bolt circle must match the mating flange. Even if two flanges have the same outside diameter, different bolt circle dimensions can prevent correct assembly.
Bolt Hole Size and Quantity
The bolt-hole diameter and number of holes determine the fastening arrangement.
These specifications vary by flange size and pressure class. The correct bolt diameter, length, thread, and material must also be verified before installation.
ASME B16.5 Blind Flange Pressure Classes
ASME B16.5 is a widely used standard for pipe flanges and flanged fittings. It covers specified flange sizes, pressure classes, materials, and dimensional requirements.
Common ASME pressure classes include:
| Pressure Class | General Description |
|---|---|
| Class 150 | Lower-pressure class |
| Class 300 | Higher rating category than Class 150 |
| Class 400 | Intermediate higher-pressure class |
| Class 600 | Higher-pressure class |
| Class 900 | High-pressure class |
| Class 1500 | Very high-pressure class |
| Class 2500 | Highest listed class in this series |
These class numbers are not direct PSI pressure ratings. For example, a Class 150 blind flange is not automatically rated for 150 PSI under every operating condition.
The allowable pressure depends on the material group and operating temperature. Always consult the applicable pressure-temperature rating tables.
How Pressure Class Affects Blind Flange Dimensions
Pressure class affects the design requirements of a blind flange.
For the same nominal size, different classes may have different:
- Outside diameters.
- Flange thicknesses.
- Bolt circle diameters.
- Bolt-hole diameters.
- Number of bolt holes.
- Facing and sealing requirements.
A Class 150 blind flange should not automatically be treated as interchangeable with a Class 300 blind flange.
Common Uses of Different Pressure Classes
Class 150: Commonly considered for suitable lower-pressure water, utility, and industrial piping applications.
Class 300: Used in applications requiring a higher pressure class than Class 150.
Class 600: Common in selected higher-pressure industrial services.
Class 900 and above: Used in specialized high-pressure systems where the design and material specifications permit their application.
The actual selection must be based on design pressure, operating temperature, material, and applicable piping code.
Types of Blind Flanges
Blind flanges are available in different facing designs and materials. Selecting the correct type depends on the mating flange and the operating conditions.
Raised Face Blind Flange
A raised face blind flange has a slightly elevated sealing surface around its outer face.
The gasket is positioned on this raised surface, and the bolts compress the gasket to create a seal.
Common characteristics include:
- Raised sealing area.
- Compatibility with specified RF mating flanges.
- Availability in several pressure classes.
- Use in many industrial piping applications.
The raised-face dimensions and gasket arrangement must match the applicable standard.
Flat Face Blind Flange
A flat face blind flange has a flat gasket-contact surface.
It is commonly used in connections designed for flat-face arrangements. Such flanges may be found in selected water systems, equipment connections, and applications involving compatible mating components.
The gasket type and material must be suitable for the system.
Ring-Type Joint Blind Flange
A ring-type joint (RTJ) blind flange has a specially machined groove designed to accommodate a metallic ring gasket.
The gasket sits inside the groove and forms a seal when the connection is properly assembled.
RTJ blind flanges are commonly used in demanding pressure applications. The groove profile, ring dimensions, material, and mating flange must be compatible.
Spectacle Blind and Figure-8 Blind
A spectacle blind is a different type of pipeline isolation component. It consists of a solid plate connected to an open spacer section, creating a figure-eight shape.
It can be rotated to either block the pipeline or allow flow, depending on the installation design.
Unlike a conventional blind flange, a spectacle blind is generally installed between flanged connections and is used where visible positive isolation is required by the system design.
Read Latest Guide:
Blind Flange Materials
Material selection is important because blind flanges must withstand the operating pressure, temperature, and environmental conditions of the piping system.
Carbon Steel Blind Flanges
Carbon steel is widely used for industrial piping applications.
Common material specifications include ASTM A105 for forged carbon steel flange products, subject to the applicable product requirements.
Typical applications include:
- General industrial piping.
- Water and utility systems.
- Oil and gas facilities.
- Selected process piping systems.
Stainless Steel Blind Flanges
Stainless steel blind flanges are selected when corrosion resistance is an important requirement.
Common grades include 304 and 316 stainless steel, with the correct product specification selected for the application.
They may be used in:
- Chemical processing.
- Food and beverage facilities.
- Water treatment.
- Corrosive service environments.
The correct stainless steel grade depends on the fluid, temperature, chloride exposure, and other operating conditions.
Alloy Steel Blind Flanges
Alloy steel blind flanges are used in specialized services where additional material properties are required.
Their selection depends on temperature, pressure, mechanical requirements, and the applicable material specification.
Comparison of Common Materials
| Material | General Characteristics | Common Applications |
|---|---|---|
| Carbon steel | General industrial strength | Water, oil, and utility piping |
| Stainless steel 304 | General corrosion resistance | Industrial and process systems |
| Stainless steel 316 | Improved resistance in many corrosive environments | Chemical and water systems |
| Alloy steel | Selected high-temperature and specialized properties | Power and industrial applications |
Material grades should never be selected based on corrosion resistance alone. The full material specification and service conditions must be reviewed.
Read Latest Guide:
How to Measure a Blind Flange
Accurate measurement helps identify an existing blind flange and determine whether a replacement will fit the connection.
Use a vernier caliper, outside measuring tape, straightedge, and suitable measuring tools.
Step 1: Measure the Outside Diameter
Measure across the widest points of the flange body, passing through its center.
Record the measurement in millimeters or inches.
Step 2: Measure the Thickness
Measure the main flange body thickness. If the flange has a raised face, record the raised-face height separately.
Do not combine the raised-face height with the main body thickness unless the specified drawing defines an overall dimension.
Step 3: Measure the Bolt Circle Diameter
Identify the centers of the bolt holes.
For an even-numbered symmetrical pattern, measure between the centers of two opposite holes. This gives the bolt circle diameter.
For patterns where opposite holes are unavailable, use the appropriate geometric measurement method or consult the dimensional drawing.
Step 4: Count the Bolt Holes
Count the total number of holes and record their arrangement.
Check whether the holes are evenly distributed and whether the pattern matches the applicable standard.
Step 5: Measure the Bolt Hole Diameter
Use a caliper to measure the diameter of the bolt holes.
The measurement should be compared with the standard drawing, including its specified tolerances.
Step 6: Identify the Facing Type
Check whether the flange has:
- Raised face (RF).
- Flat face (FF).
- Ring-type joint (RTJ).
For RTJ designs, the groove dimensions and ring identification are especially important.
Step 7: Verify the Standard and Pressure Class
Look for identification markings, manufacturer details, material specifications, and pressure class.
If markings are unavailable, compare all measured dimensions with the relevant dimensional standard before selecting a replacement.
Read Latest Guide:
How to Select the Correct Blind Flange
Choosing a suitable blind flange requires checking more than its nominal size.
1. Confirm the Nominal Size
Identify the required NPS or DN designation from the piping drawing, equipment documentation, or existing flange specification.
2. Check the Pressure Class
Confirm the design pressure and operating temperature. Use the material-specific pressure-temperature tables to determine the required flange class.
3. Match the Facing
The blind flange and mating flange must have compatible sealing surfaces. Select the appropriate gasket for the facing and service.
4. Verify the Bolt Pattern
Check the outside diameter, bolt circle diameter, hole diameter, and number of holes.
These dimensions must match the mating flange.
5. Select the Correct Material
Choose a material suitable for the fluid, temperature, pressure, corrosion conditions, and applicable engineering requirements.
6. Check the Manufacturing Standard
Confirm whether the connection uses ASME B16.5, ASME B16.47, EN 1092-1, or another specification.
Do not assume that similar nominal sizes from different standards have identical dimensions.
7. Confirm the Gasket and Fasteners
The gasket, bolts, and nuts must be suitable for the flange design and operating conditions. Follow the specified assembly procedure and tightening requirements.
Applications of Blind Flanges
Blind flanges are used across different industries because they provide a removable closure for flanged connections.
Common applications include:
- Oil and gas: Closing pipeline ends, equipment connections, and selected process openings.
- Water treatment: Closing unused pipe connections and equipment outlets.
- Chemical plants: Isolating selected piping connections for maintenance.
- Power generation: Closing specified steam, water, and utility piping connections.
- Petrochemical facilities: Providing removable closures in process piping.
- Manufacturing plants: Closing equipment nozzles and unused pipeline branches.
- Marine systems: Closing suitable piping connections in marine installations.
Blind flanges used for isolation must be selected and installed according to the required safety and isolation procedures.
Common Blind Flange Sizing Mistakes
Incorrect identification can result in installation problems, leakage, or an unsuitable pressure-containing component.
Avoid the following mistakes:
- Matching only the outside diameter: Bolt patterns and thickness must also be checked.
- Ignoring the pressure class: Different classes can have different dimensions and ratings.
- Confusing NPS with actual diameter: NPS is a nominal designation.
- Mixing flange standards: ASME and EN dimensions may differ.
- Selecting the wrong facing: RF, FF, and RTJ arrangements are not automatically interchangeable.
- Ignoring material requirements: The material must suit the operating environment.
- Using an unsuitable gasket: Gasket compatibility is essential for proper sealing.
- Overlooking bolt specifications: Fastener size, grade, and thread requirements must be verified.
- Assuming every blind flange has the same thickness: Thickness varies with size, class, and standard.
A complete dimensional and material check should be performed before purchasing or installing a replacement flange.
Frequently Asked Questions
1. What is a blind flange used for?
A blind flange is used to close the end of a pipe, valve, pressure vessel nozzle, or other flanged connection. It provides a removable closure for inspection, maintenance, or future system modifications.
2. How do I identify a blind flange size?
Check its nominal size, outside diameter, thickness, bolt circle diameter, bolt-hole count, facing, and pressure class. Compare these measurements with the applicable flange standard.
3. What is the difference between a blind flange and a regular flange?
A regular pipe flange generally has a central opening that allows fluid to pass through. A blind flange is solid and has no central bore, so it blocks the connected opening.
4. Does a blind flange have a pipe bore?
No. A conventional blind flange has a solid body without a central flow opening. Its purpose is to close the connection.
5. What is the difference between Class 150 and Class 300 blind flanges?
They belong to different pressure classes and may have different dimensional requirements and pressure-temperature ratings. They should not be assumed interchangeable.
6. What standard covers blind flange dimensions?
ASME B16.5 covers many commonly used blind flanges within its specified size and pressure-class scope. Larger flange applications may fall under ASME B16.47, while EN 1092-1 is used in many metric-based systems.
7. Are blind flange dimensions the same for all materials?
Not necessarily. The dimensional standard and pressure class establish the relevant dimensions, while the material specification establishes material requirements. Special products may have different designs and dimensions.
8. Can a blind flange be reused?
A blind flange may be reused if it remains within the applicable dimensional and material requirements and has no unacceptable damage, corrosion, deformation, or sealing-surface defects. Its suitability should be assessed before reuse.
9. Which gasket is used with a blind flange?
The gasket depends on the flange facing, pressure, temperature, fluid, and applicable specifications. RF, FF, and RTJ connections require compatible gasket arrangements.
10. Is a blind flange suitable for permanent pipe closure?
It can be used for long-term closure when properly specified and installed. However, the connection must meet the system’s design and safety requirements.
Conclusion
A Blind Flange Size Chart is a useful reference for identifying nominal sizes, DN equivalents, and the measurements required to select a compatible flange. However, the correct choice also depends on pressure class, material, facing type, bolt pattern, thickness, and manufacturing standard.
Before purchasing or installing a blind flange, verify its complete dimensions against the mating flange and applicable technical documentation. Proper selection, gasket compatibility, and correct installation help provide a reliable piping connection.